search

TWO BOILERS FOR WASTE HEAT RECOVERY WITH A TRIPLE-PRESSURE SYSTEM AND STEAM REHEATING (MELLACH, AUSTRIA)

reference detail image
reference detail map
End user:
Siemens Power Generation Anlagentechnik GmbH
Completed:
2011

2x Heat Recovery Steam Generator (HRSG)

  • 266,6 / 300,6 / 40,5 t/h
  • 129,5 / 29,9 / 4,3 bar(a)
  • 559,6 / 560 / 226 °C
  • horizontal
  • triple pressure with reheat

Gas turbine: SGT5 – 4000F