2 x HRHWB, 1x heat accumulator
- 2x 116 MWth, 1x 575 MWth
- 135/60 °C hot water temperature, 12,000 m3 water volume
- vertical
- supplementary firing (70 MWth)
Gas turbine: LM 6000 PF
UNIS ACTIVITIES
Complete delivery of boilers. DH system including BoP, pumping station and heat accumulator.